Intraocular Pressure and Photorefractive Keratectomy: A Comparison of Three Different Tonometers.

Submitted by dave on Fri, 12/15/2006 - 3:46pm
Cornea. 20(1):33-36, January 2001.
Garzozi, Hanna J. M.D.; Chung, Hak S. M.D., Ph.D.; Lang, Yaron M.D.; Kagemann, Larry M.S., B.M.E.; Harris, Alon Ph.D.

Abstract:
Purpose. To evaluate the intraocular pressure (IOP) with three different instruments, Goldmann applanation tonometer (GAT), noncontact tonometer, and Tono-Pen after photorefractive keratectomy (PRK) for myopia.

Comparison of intraocular pressure measured by non-contact air puff versus Goldmann applanation tonometers in gas-filled vitrect

Submitted by dave on Fri, 12/15/2006 - 3:43pm

OBJECTIVE: To compare intraocular pressure (IOP) measured by two different instruments, air puff tonometer (NCT) versus Goldmann applanation tonometer (GAT), in gas-filled vitrectomized eyes.

DESIGN: Three-month, prospective, comparative trial.

Clinical Evaluation of the New TGDc-01 "PRA" Palpebral Tonometer: Comparison with Contact and non-Contact Tonometry.

Submitted by dave on Fri, 12/15/2006 - 2:36pm

Optometry & Vision Science. 82(2):143-150, February 2005.
RESUA, CARLOS GARCIA OD; FERNANDEZ, MARIA J. GIRALDEZ OD; EXPOSITO, ALEJANDRO CERVINO OD; PEREZ, JAVIER GONZALEZ OD; YEBRA-PIMENTEL, EVA OD, PhD

Assessment of the accuracy and reliability of the Topcon CT80 non-contact tonometer.

Submitted by dave on Fri, 12/15/2006 - 2:18pm

BACKGROUND: The reliability of non-contact tonometers has been reported extensively in the literature. This study was designed to assess reliability of the new Topcon CT80 non-contact tonometer in normotensive subjects, using the Goldmann tonometer as the standard.

Comparison of the ICare((R)) rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometr

Submitted by dave on Fri, 12/15/2006 - 2:15pm

 

Purpose: To assess the agreement between ICare((R)) rebound tonometer and Goldmann applanation tonometer in the hands of experienced and inexperienced tonometrists.

Patients and methods: Two tonometrists, experienced with both Goldmann applanation tonometry (GAT) and ICare(R) Tonometry (ICT) measured intraocular pressure (IOP), in a masked fashion, in 100 patients. In another series of 58 patients, ICT was performed by an inexperienced tonometrist and GAT by an experienced tonometrist.

Inter-instrument agreement and influence of central corneal thickness on measurements with Goldmann, pneumotonometer and noncont

Submitted by dave on Fri, 12/15/2006 - 2:11pm

PURPOSE: This study was conducted to compare the intraocular pressure (IOP) measurements by the Goldman applanation tonometer (GAT), non contact tonometer (NCT) and the ocular blood flow (OBF) pneumotonometer in different IOP ranges in glaucomatous eyes. The effect of central corneal thickness (CCT) on IOP measurement in chronic glaucomatous eyes using the three different tonometers was also evaluated.

Inter-instrument agreement and influence of central corneal thickness on measurements with Goldmann, pneumotonometer and noncont

Submitted by dave on Fri, 12/15/2006 - 2:11pm

PURPOSE: This study was conducted to compare the intraocular pressure (IOP) measurements by the Goldman applanation tonometer (GAT), non contact tonometer (NCT) and the ocular blood flow (OBF) pneumotonometer in different IOP ranges in glaucomatous eyes. The effect of central corneal thickness (CCT) on IOP measurement in chronic glaucomatous eyes using the three different tonometers was also evaluated.

Reproducibility of dynamic contour tonometry. Comparison with TonoPenXL and Goldmann applanation tonometry - a clinical study on

Submitted by dave on Fri, 12/15/2006 - 2:09pm

BACKGROUND: The PASCAL Dynamic Contour Tonometer (DCT) is a new diagnostic approach for the digital measurement of intraocular pressure (IOP) in eyes with glaucoma. The aim of this study was to evaluate the reproducibility of DCT in normal eyes and to compare DCT with Goldmann applanation tonometry (GAT) and TonoPenXL.

Blowing Your Horn Bad For IOP?

Submitted by dave on Sat, 12/09/2006 - 9:02pm

Increased intraocular pressure and visual field defects in high resistance wind instrument players

Joel S. Schuman MD, Emma Craig Massicotte MD, Shannon Connolly BA, Ellen Hertzmark MS, Bhaskar Mukherji MD and Mandi Z. Kunen MD

New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts., USA 

Received 23 March 1999; accepted 30 August 1999 Manuscript no. 99154. Available online 10 January 2000. 

 

Filed Under (tags):

Drugs Affecting Pupil Diameter Influence GDx Results

Submitted by dave on Sat, 12/09/2006 - 9:02pm

Make sure your GDx tests are performed under similar conditions in regard to any medications that affect your pupil size.

Influence of Pupillary Diameter, Ciliary Muscle Tone, and Ambient Light on Nerve Fiber Layer Measurements With Scanning Laser Polarimetry

Paranhos A Jr, Silvestre AM, Passerotti CC, Martins EM, Mello PA, Prata JA Jr, Shields MB.

Filed Under (tags):

Breathing "Right" Lowers IOP In Study

Submitted by dave on Sat, 12/09/2006 - 8:59pm

As I understand this study, the researchers had subjects with primary open angle glaucoma (POAG) breathe through their right nostril only (by closing off their left nostril). There is a common breathing technique in Yoga know as "alternate nostril breathing" or Nadi Shodhana in sanskrit. The aim of alternating the open nostrils is to create balance in the physiology. The idea behind the method used in this study is to correct a (perceived) imbalance by breathing through the right nostril only.